{
    "schemaVersion": "ooitech-article.v1",
    "url": "https://www.ooitech.com/uv-dose-iec-tests-outdoor-months.html",
    "language": "en",
    "title": "UV Dose in IEC Tests: How Many Months Outdoors?",
    "description": "IEC UV tests report hours and irradiance. Converted to outdoor months, 15 kWh/m2 is 1.4 to 2.5 months, and a real year is 72 to 133 kWh/m2.",
    "keywords": "UV dose, IEC 61215, MQT10, kWh/m2, UV aging test, module reliability",
    "ogType": "website",
    "image": "https://cdn.ooitech.com/static/upload/image/20261105/uv-dose-iec-tests-outdoor-months.png",
    "headings": [
        {
            "level": 1,
            "text": "UV Dose in IEC Tests: How Many Months Outdoors?"
        },
        {
            "level": 2,
            "text": "UV Dose in IEC Tests: How Many Months Outdoors?"
        },
        {
            "level": 2,
            "text": "Why Dose Replaced Hours in the Lab Report"
        },
        {
            "level": 3,
            "text": "Where the 4.6 Percent Ratio Comes From"
        },
        {
            "level": 2,
            "text": "What One Outdoor Year Actually Delivers"
        },
        {
            "level": 2,
            "text": "MQT10 in Outdoor Months"
        },
        {
            "level": 2,
            "text": "MQT10 Is a Preconditioning Step, Not a Lifetime Test"
        },
        {
            "level": 2,
            "text": "Installation Geometry Moves the Dose as Much as Latitude"
        },
        {
            "level": 3,
            "text": "Tilt, Tracking and Diffuse Light"
        },
        {
            "level": 2,
            "text": "Spectrum Decides Which Path You Test"
        },
        {
            "level": 3,
            "text": "Band Limits and the 365 Nanometer Habit"
        },
        {
            "level": 3,
            "text": "Incident Dose Versus Transmitted Dose"
        },
        {
            "level": 2,
            "text": "Temperature and Dark Recovery Share the Blame"
        },
        {
            "level": 2,
            "text": "The Five Item Reporting Checklist"
        },
        {
            "level": 2,
            "text": "What This Means for TOPCon UVID Claims"
        },
        {
            "level": 2,
            "text": "Where These Numbers Come From"
        },
        {
            "level": 2,
            "text": "Frequently Asked Questions"
        },
        {
            "level": 3,
            "text": "Q: Is 15 kWh/m2 the same for every module?"
        },
        {
            "level": 3,
            "text": "Q: Why not just quote hours of exposure?"
        },
        {
            "level": 3,
            "text": "Q: Does a higher dose always mean more degradation?"
        },
        {
            "level": 3,
            "text": "Q: How many outdoor years does IEC TS 63209-1 cover?"
        },
        {
            "level": 3,
            "text": "Q: Is the 4.6 percent UV share of AM1.5G wrong?"
        },
        {
            "level": 3,
            "text": "Q: Does this apply to glass glass modules only?"
        },
        {
            "level": 3,
            "text": "Q: What lamp should a UV test use?"
        },
        {
            "level": 3,
            "text": "Q: Where can I get the dose for my own site?"
        },
        {
            "level": 2,
            "text": "Final Thoughts"
        },
        {
            "level": 5,
            "text": "Tags :"
        },
        {
            "level": 5,
            "text": "Table of Contents"
        },
        {
            "level": 5,
            "text": "Category"
        },
        {
            "level": 5,
            "text": "Related Posts"
        },
        {
            "level": 6,
            "text": "IV Curve Testing: How to Measure a Solar Module"
        },
        {
            "level": 6,
            "text": "Solar Panel Hot Spots: Why Temperature Matters"
        },
        {
            "level": 6,
            "text": "Finger Interruptions in Solar Cells — EL Testing"
        },
        {
            "level": 6,
            "text": "Solar Simulator Calibration: How Often and How To"
        },
        {
            "level": 6,
            "text": "FF in Solar Cell: What Fill Factor Reveals"
        },
        {
            "level": 5,
            "text": "Recent Post"
        },
        {
            "level": 6,
            "text": "UV Dose in IEC Tests: How Many Months Outdoors?"
        },
        {
            "level": 6,
            "text": "Two-Year-Old BC Stringer, Retrofitted for All-Black Modules"
        },
        {
            "level": 6,
            "text": "Qualifying a New Encapsulant Film: Four Gates to Volume"
        },
        {
            "level": 5,
            "text": "Popular Tags"
        },
        {
            "level": 3,
            "text": "Request A Quote"
        },
        {
            "level": 2,
            "text": "We deliver expertise you can trust our service"
        },
        {
            "level": 3,
            "text": "Cost-Effective Advantages"
        },
        {
            "level": 3,
            "text": "Our Experience Team"
        },
        {
            "level": 3,
            "text": "15+ Years Industry Experience"
        },
        {
            "level": 2,
            "text": "What Our Client Say's about us"
        },
        {
            "level": 3,
            "text": "Jizzakh Polytechnic Institute"
        },
        {
            "level": 3,
            "text": "Amjad"
        },
        {
            "level": 3,
            "text": "Diarra From Africa"
        },
        {
            "level": 3,
            "text": "KTECH"
        },
        {
            "level": 3,
            "text": "Mark"
        },
        {
            "level": 2,
            "text": "Our Latest Products"
        },
        {
            "level": 3,
            "text": "Solar Panel Production Line: Configurations from 5 MW to 1 GW"
        },
        {
            "level": 3,
            "text": "Non-Destructive Solar Cell Laser Cutting Machine"
        },
        {
            "level": 3,
            "text": "Solar Cell Layup Machine WS-CL80D: 48s Cycle, ±0.1mm"
        },
        {
            "level": 3,
            "text": "Automatic Tape Sticking Machine: 25s Cycle, ±2mm"
        },
        {
            "level": 3,
            "text": "String Interconnect: Solar Busbar Ribbon Guide"
        },
        {
            "level": 3,
            "text": "OPT-M960B EL & VI Tester: 0.1mm/pixel, Intel i7"
        }
    ],
    "wordCount": 3601,
    "markdown": "# UV Dose in IEC Tests: How Many Months Outdoors?\n\n> IEC UV tests report hours and irradiance. Converted to outdoor months, 15 kWh/m2 is 1.4 to 2.5 months, and a real year is 72 to 133 kWh/m2.\n\n![UV Dose in IEC Tests: How Many Months Outdoors?](https://cdn.ooitech.com/static/upload/image/20261105/uv-dose-iec-tests-outdoor-months.png)\n\n- ** Ooitech Editorial Team\n- ** 2026-11-26\n- ** 0 Views\n- ** [Electrical & Fundamentals](./Electrical-Fundamentals.html)\n\nEditorial responsibility for this article rests with **Wuhan Ooi Photoelectric Technology Co., Ltd.** Written and reviewed by the Ooitech editorial team. See our [editorial policy](/editorial-policy.html) for how we write, where AI tools are used, and how to request a correction.\n\n## UV Dose in IEC Tests: How Many Months Outdoors?\n\n**Quick answer:** A UV chamber report names a lamp, an irradiance and a number of hours. Durability depends on none of those directly. It depends on the cumulative dose in kilowatt hours per square meter, and on which wavelengths carry that dose. A 2026 analysis of US outdoor ultraviolet radiation puts the annual horizontal dose between 280 and 400 nm at 72.1 kWh/m2 in Washington state and 133.3 kWh/m2 in southern New Mexico, with a median near 100. Against that ruler, the 15 kWh/m2 UV preconditioning step in IEC 61215-2 takes a horizontally mounted module 1.4 to 2.5 months to collect outdoors, not years. Measured UV is also 5.5 to 6.5 percent of global horizontal irradiance, above the 4.6 percent ratio often assumed from AM1.5G, which makes fixed ratio estimates optimistic. The fix is a reporting habit: four spectral band doses, a named outdoor reference year with its mounting geometry, and the device temperature.\n\nA chamber report answers a narrow question: was the sample exposed to the lamp long enough for this protocol. It does not answer the buyer's question, which is how long the same module would have to stand outside to collect an equivalent dose.\n\nAnnual UV dose at 280 to 400 nm on a horizontal plane, against the 15 kWh/m2 MQT10 step.\n\n## Why Dose Replaced Hours in the Lab Report\n\nDose is irradiance multiplied by time, expressed in kilowatt hours per square meter. Two chambers that deliver 100 W/m2 for 100 hours and 1,000 W/m2 for 10 hours both accumulate 10 kWh/m2, and they are not the same experiment. Rate sets device temperature, the oxygen available at the interface, and how much of the damage recovers in the dark. Dose is the comparable part. Rate is the part a report has to state separately.\n\nA 2026 review of 33 ultraviolet studies on perovskite devices shows why quoting hours stopped traveling well. Irradiances in that literature run from 1 to 600 mW/cm2 and exposures from 20 minutes to 2,200 hours. Converted, the doses span more than four orders of magnitude, and 7 of the 33 papers do not contain enough information to compute a dose at all. The rest divide across five conventions in total, so a table that lines up exposures from different papers is often comparing numbers that were never meant to be compared.\n\n- Multiples of the IEC 61215-2 preconditioning step, which hides irradiance and spectrum behind a ratio.\n- A fixed 4.6 percent share of global horizontal irradiance, taken from the AM1.5G reference spectrum.\n- Irradiance and time only, with no reference year, which leaves the reader to guess the outdoor equivalent.\n\nEach convention can be defended on its own. None of them transfers between papers, and none answers how long a module would need outdoors to collect the same dose. The rest of this article converts the numbers into months at real sites, and shows where the conversion breaks.\n\n### Where the 4.6 Percent Ratio Comes From\n\nThe 4.6 percent figure is honest arithmetic. Integrate the AM1.5G reference spectrum between 280 and 400 nm, divide by the total, and that is the share. It is popular because annual global horizontal irradiance is available for any location from a database, so one multiplication produces a dose.\n\nField spectra do not hold that ratio. Across the US grid the measured UV share runs from 5.5 to 6.5 percent of global horizontal irradiance, with a median near 5.9. Integrating measured spectra against satellite irradiance gives 1.19 to 1.41 times what the fixed ratio predicts, and the gap is widest at altitude, where thin air passes more of the short wavelengths. A report that multiplies annual irradiance by 4.6 percent is not conservative at mountain sites. It is short by about a factor of 1.4.\n\n## What One Outdoor Year Actually Delivers\n\nThe reference year below combines satellite meteorology with a narrowband spectral model on a 1.5 degree grid, 2018 to 2024, integrated from 280 to 400 nm for a horizontal plane.\n\n| Site or region | Annual UV dose, horizontal plane (kWh/m2) |\n| --- | --- |\n| Washington state, US | 72.1 |\n| US continental median | about 100 |\n| Southern New Mexico, US | 133.3 |\n| Berlin | about 58 |\n| Beijing | about 85 |\n| Central Australia | about 140 |\n| Andes, high altitude | up to 166 |\n\nHeld against that ruler the range is not decorative. A module in Berlin collects 58 kWh/m2 in a year, and the same module in central Australia collects 140. Both can pass the same recipe. Roughly 83 percent of the world's land area falls inside the US range.\n\nAny annual dose in a report therefore needs a location and a mounting geometry attached to it, or it is not a number a buyer can use.\n\n## MQT10 in Outdoor Months\n\nThis table converts the common lab conditions into months of horizontal outdoor exposure at the US median site and at the two US extremes.\n\n| Lab condition | Dose (kWh/m2) | Months outdoors, US horizontal |\n| --- | --- | --- |\n| IEC 61215-2 MQT10 | 15 | 1.4 to 2.5 |\n| 60 mW/cm2 for 30 h | 18 | about 2 at Golden, CO |\n| A claimed 5.4 times IEC | 81.6 | 7 to 14 |\n| One year at the median site | about 100 | 12, or 6.7 times MQT10 |\n| IEC TS 63209-1 extended stress | 60 to 160 | about 6 to over 24 |\n\nStarting on January 1 with the module flat, 15 kWh/m2 is reached in early March in southern New Mexico and in late April in Washington state. The 18 kWh/m2 case, 60 mW/cm2 for 30 hours, lands at about two months at Golden, Colorado. A test that reads as a longer exposure is again a season.\n\nThe same arithmetic applies to the studies. Of 26 papers whose dose can be computed, 18 sit below one outdoor year. Of the 6 that exceed it, 5 used irradiances of 50 to 600 mW/cm2, between 11 and 130 times the UV in AM1.5G, and at those levels sample self heating opens degradation channels that outdoor modules do not see.\n\n## MQT10 Is a Preconditioning Step, Not a Lifetime Test\n\nIEC 61215-2 MQT10 exists to expose weaknesses in the encapsulation before [the reliability test list](https://www.ooitech.com/pv-module-reliability-tests-list-cell-vs-module-failure-causes.html) moves on to thermal cycling and humidity: yellowing, loss of adhesion, and the [line shaped bubbles along the ribbons](https://www.ooitech.com/epe-encapsulant-lamination-delamination-line-shaped-bubbles-along-solar-cell-ribbons.html). Fifteen kilowatt hours provokes those failures in a bad laminate and runs in a few days. MQT10 sits early in the sequence for that reason, before the module has aged into a different failure mode. Passing says the module survived the screen. It does not say the module lasts 25 years.\n\nTo prevent ribbon bubbles during 15 kWh/m2 testing, we optimize the evacuation duration and press profile, ensuring complete crosslinking across the glass area before the module enters ultraviolet chambers.\n\nThe extended stress sequence in IEC TS 63209-1 runs from 60 to 160 kWh/m2, which is closer to real service and still a fraction of a warranty. A defect found after a UV step deserves a diagnosis before it is blamed on the film, since [not every laminate bubble is the film fault](https://www.ooitech.com/not-every-laminate-bubble-is-the-encapsulants-fault-the-real-causes-behind-solar-module-bubbles.html).\n\n## Installation Geometry Moves the Dose as Much as Latitude\n\nLatitude sets the annual total. Mounting decides how much of it lands on the glass.\n\n### Tilt, Tracking and Diffuse Light\n\nRelative to a horizontal plane, a fixed tilt adds 2 to 5 kWh/m2 per year, single axis tracking adds about 10, dual axis tracking about 18, and the gain reaches 35 in high irradiance regions. Steeper tilt buys less than the tracking numbers suggest, because it also gives up diffuse sky light, and diffuse light is rich in UV.\n\nA report that says five years equivalent without naming the geometry can be off by a third. Rear side dose for bifacial modules and ground albedo were outside the paper's scope. On a tracker the total rises while the diffuse share falls, so the spectral mix shifts along with the dose.\n\n## Spectrum Decides Which Path You Test\n\nDose counts photons. Where those photons land decides which degradation path runs.\n\n### Band Limits and the 365 Nanometer Habit\n\nSplit the outdoor spectrum and wavelengths below 320 nm carry about 4 percent of the UV dose, below 340 nm about 22 percent, and the 360 to 400 nm band about 56 percent. A dose integrated only to 365 nm is roughly half of the 400 nm dose, so two reports can quote the same number and test different physics.\n\nPhoton energy matters as much as photon count. About 19 percent of outdoor UV photons exceed 3.65 eV. A 365 nm LED delivers 3.40 eV, below the 3.6 to 4.0 eV bandgap of SnO2 and at the lower bound of NiOx, so it cannot excite the above gap response in those transport layers. Of 13 p-i-n studies published since 2025, 9 used only 365 nm. The recommendation is a UVA-340 fluorescent lamp or filtered xenon, with the duty cycle stated.\n\n### Incident Dose Versus Transmitted Dose\n\nWhat reaches the cell is not what reaches the glass. Iron content in the front glass and the angle of incidence both change the transmitted spectrum, and the rear of a bifacial module sees a third version of it. Reporting incident dose alone leaves a reader unable to compare two stacks, which is where the front glass specification and [the lamination stack](https://www.ooitech.com/solar-panel-production-process-lamination.html) become part of the UV result.\n\n## Temperature and Dark Recovery Share the Blame\n\nDose equivalence assumes reciprocity, meaning the same total produces the same damage at any rate. A widely cited comparison breaks that assumption. Perovskite cells held near 94 percent of initial efficiency after about 34 kWh/m2 indoors, then fell to 66 to 75 percent after 26 weeks outdoors with only 1.3 to 1.5 times the indoor UV. Something other than UV was doing the work, and the obvious candidate is temperature under illumination. Jiang and colleagues reported that comparison in Nature in 2023, volume 623, pages 313 to 318.\n\nDevice temperature outdoors follows the mounting and the backsheet. In a chamber it follows the platen, the airflow and the lamp load, which belong to [the laminator and its platen](https://www.ooitech.com/single-layer-double-chamber-automatic-bipv-laminator-otcy-2754dd-ooitech-solar-panel-lamination-equipment.html) rather than to the sample. Dark recovery before measurement is the other unstated variable: some damage anneals overnight, so a test that measures immediately after exposure reports a worse result than one that waits.\n\n## The Five Item Reporting Checklist\n\nFive fields turn a UV claim into something a buyer can compare. The authors propose them as a minimum, not as a format.\n\n| Item | What to report | Why it changes the answer |\n| --- | --- | --- |\n| Spectrum | Lamp type and spectrum, dose in 280 to 320, 320 to 340, 340 to 360 and 360 to 400 nm | Band limits alone move the dose by a factor of two |\n| Dose | Total in kWh/m2, plus irradiance, time and detector position | A ratio to a preconditioning step hides both |\n| Duty cycle and temperature | Continuous or cyclic exposure, device temperature on and off, recovery before measurement | Rate and annealing change the outcome at equal dose |\n| Outdoor reference | Site and mounting geometry, plus the annual dose used for conversion | Geometry alone spans 35 kWh/m2 per year |\n| Device stack | Illuminated face, filters, glass type and iron content, incident or transmitted | Transmitted dose is the one the cell sees |\n\nApplied to a supplier claim, the table is unforgiving. A sentence such as five times the IEC requirement becomes checkable: 75 kWh/m2 is about nine months at the median US site, six months in southern New Mexico, and over a year in Washington state.\n\n## What This Means for TOPCon UVID Claims\n\nModule level UV requirements are being tightened at the same time. A 60 kWh/m2 requirement, now common in supplier specifications for TOPCon products, is about 0.6 of one outdoor year at the median US site and 0.45 of a year in southern New Mexico. That is a reasonable screen for encapsulation and for front side passivation, and a short exposure for anything that needs years.\n\nTo help TOPCon modules survive 60 kWh/m2 exposure without edge delamination, we run multi-stage temperature profiles that prevent thermal stress and maintain uniform gel content from center to corner.\n\nDose is still not lifetime. Turning a dose into a predicted loss needs an action spectrum for the specific stack, and no published action spectrum covers a modern TOPCon or perovskite tandem stack.\n\nTwo gaps stay open. The analysis covers the continental US, so sites in China, India and the Middle East are reached by extrapolation, and Beijing at about 85 kWh/m2 is the only Asian reference quoted. High altitude and tracking installations, where the dose is highest, are also where the conversion is least tested. Both are arguments for measuring at the site instead of multiplying. Rear side UV on bifacial modules and frame shading are not in the model at all.\n\n## Where These Numbers Come From\n\nThe dose map, the conversion tool and the checklist come from Witteck, Nguyen Minh, Owen-Bellini, Luther and Schelhas, published in ACS Energy Letters in 2026 under DOI 10.1021/acsenergylett.6c02742. Their review covers 33 UV studies on perovskite devices. The outdoor numbers combine National Solar Radiation Database meteorology with a narrowband spectral model on a 1.5 degree grid for 2018 to 2024, checked against spectroradiometer records at Golden, Colorado and Eugene, Oregon.\n\nAgainst the IEC 62788-7-2 reference stations the modeled annual doses agree within about 5 percent. The recommended reference year is 100 kWh/m2 for a horizontal plane at the US median, or 110 kWh/m2 for the Golden 40 degree tilt used in that standard. The dose map and conversion tool are published openly, with the code on GitHub under NatLabRockies/pv-uv-dose. Two checklist items, duty cycle and dark recovery, are recommendations rather than measured results.\n\n## Frequently Asked Questions\n\n### Q: Is 15 kWh/m2 the same for every module?\n\nA: No. It is the dose in IEC 61215-2 MQT10, which is a fixed recipe. The outdoor equivalent depends on the site, so 15 kWh/m2 spans 1.4 to 2.5 months across the US range and closer to 3 months in Berlin.\n\n### Q: Why not just quote hours of exposure?\n\nA: Hours only compare tests run at the same irradiance with the same spectrum. Two labs at 100 and 600 mW/cm2 can report identical hours and deliver six times different doses.\n\n### Q: Does a higher dose always mean more degradation?\n\nA: Not linearly. Above roughly 50 mW/cm2 self heating changes the mechanism, and some damage anneals in the dark, so equal doses delivered at very different rates can rank differently.\n\n### Q: How many outdoor years does IEC TS 63209-1 cover?\n\nA: Its extended UV stress runs from 60 to 160 kWh/m2, which is about half a year to more than two years at the US median, depending on where the sequence lands.\n\n### Q: Is the 4.6 percent UV share of AM1.5G wrong?\n\nA: It is correct for that reference spectrum. It is not a valid conversion factor for a location, where measured UV runs 5.5 to 6.5 percent of global horizontal irradiance.\n\n### Q: Does this apply to glass glass modules only?\n\nA: The dose arithmetic applies to any module. The transmitted spectrum depends on the front glass and the degradation path depends on the cell stack, so the conversion is the shared part.\n\n### Q: What lamp should a UV test use?\n\nA: The paper points to UVA-340 fluorescent or filtered xenon, with band doses reported. A 365 nm LED alone cannot excite above gap response in SnO2 or at the lower bound of NiOx.\n\n### Q: Where can I get the dose for my own site?\n\nA: From the open dose map and conversion tool released with the paper, or from a spectral model run on satellite irradiance. Reporting the value with its mounting geometry is the part that matters.\n\n## Final Thoughts\n\nAsk for the dose, the band limits and the reference site before reading any UV claim, and the numbers stop being interchangeable. A preconditioning step becomes a screen, an extended stress test becomes a shorter field life, and a supplier claim becomes something a buyer can check against a public map. The arithmetic is the easy part. Writing down which year, where, and how mounted is what changes a specification.\n\nOOITech manufactures single and double chamber [solar panel laminator machines](https://www.ooitech.com/solar-panel-laminator-machine.html) with electric or thermal oil heating to deliver uniform thermal control for delicate module stacks. If you are qualifying encapsulation materials or refining your curing recipe, send us your module stack specifications, component drawings, or laminate samples for technical evaluation and process testing.\n\n---\n\n##### Tags :\n\n![](/template/ooitech/assets/img/shape/06.png)\n\n![](https://cdn.ooitech.com/runtime/image/w800_h700_fitblur_v2_w800_h700_fitblur_v2_1757399770541443.webp)\n\n### Request A Quote\n\nAll uploads are secure and confidential.\n\n## We deliver expertise you can trust our service\n\nDirect-from-Factory Equipment.\n\n![](/template/ooitech/assets/img/icon/money-2.svg)\n\n### Cost-Effective Advantages\n\nWe deliver exceptional value, maximizing results while optimizing budgets for clients.\n\n![](/template/ooitech/assets/img/icon/staff.svg)\n\n### Our Experience Team\n\nOur skilled professionals specialize in innovative solutions and tailored strategies.\n\n![](/template/ooitech/assets/img/icon/certified.svg)\n\n### 15+ Years Industry Experience\n\nDeep expertise ensures reliable, trend-aware, and proven outcomes for success.\n\n![](https://cdn.ooitech.com/static/upload/image/20250910/1757477357667605.webp )\n\n![](https://cdn.ooitech.com/static/upload/image/20250910/1757477724911512.webp)\n\n![](/template/ooitech/assets/img/shape/06.png)\n\n## What Our Client Say's about us\n\nClient testimonials praise our deep understanding of their challenges, which leads to innovative solutions and strong ROI. Long-term collaborations—some over a decade—demonstrate their trust and satisfaction. Their success stories drive us to continually exceed expectations. [Know More **](#quote-form)\n\n![](/template/ooitech/assets/img/icon/quote.svg)\n\nA man with a big soul. Thank you very much for your visit Mr Wu. Thank you very much for the services provided in installing equipment and training my students. The kindest person and professional in his field\n\n![](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_2026041716444445.webp)\n\n### Jizzakh Polytechnic Institute\n\n![](/template/ooitech/assets/img/icon/quote.svg)\n\nThanks to Ooitech for providing the fully automated production equipment—your installation and after-sales service have been excellent.\n\n![](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_2026041720921238.webp)\n\n### Amjad\n\n![](/template/ooitech/assets/img/icon/quote.svg)\n\nthank you for ooitech's professional support and on time after service.\n\n![](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_1784509010217979.webp)\n\n### Diarra From Africa\n\n![](/template/ooitech/assets/img/icon/quote.svg)\n\nThanks to Ooitech for providing highly suitable BC solar cell experimental equipment.\n\n![](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_1776426122864564.webp)\n\n### KTECH\n\n![](/template/ooitech/assets/img/icon/quote.svg)\n\nThank you again so much again for the very big big help for improving and fixing the factory and also teaching the workers how to use the machines\n\n![](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_1757479675272137.webp)\n\n### Mark\n\nBIPV Philippines\n\n## Our Latest Products\n\n![Solar Panel Production Line: Configurations from 5 MW to 1 GW](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_2026032510951634.webp)\n\n- [** ooitech](./solar-panel-production-line.html)\n- [** 143](./solar-panel-production-line.html)\n\n### Solar Panel Production Line: Configurations from 5 MW to 1 GW\n\nSolar panel production line guide: stations, semi-automatic vs automatic, 5 MW to 1 GW configurations, layout, utilities, staffing and RFQ tips.\n\n![Non-Destructive Solar Cell Laser Cutting Machine](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_1774252043927784.webp)\n\n- [** ooitech](./GYM-HP8000-Non-Destructive-Solar-Cell-Laser-Cutting-Machine-Advanced-TCS-Technology-for-High-Efficiency-Cell-Production.html)\n- [** 47512](./GYM-HP8000-Non-Destructive-Solar-Cell-Laser-Cutting-Machine-Advanced-TCS-Technology-for-High-Efficiency-Cell-Production.html)\n\n### Non-Destructive Solar Cell Laser Cutting Machine\n\nProfessional non-destructive solar cell laser cutting machine GYM-HP8000 with TCS technology, achieving 7600pcs/h capacity, 0.03% breakage rate\n\n![Solar Cell Layup Machine WS-CL80D: 48s Cycle, ±0.1mm](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_1774318047382785.webp)\n\n- [** Rachael](./automatic-solar-cell-layup-machine-ws-cl80d-high-speed-mbb-half-cell-string-laying-equipment-for-solar-panel-production-line.html)\n- [** 12604](./automatic-solar-cell-layup-machine-ws-cl80d-high-speed-mbb-half-cell-string-laying-equipment-for-solar-panel-production-line.html)\n\n### Solar Cell Layup Machine WS-CL80D: 48s Cycle, ±0.1mm\n\nOoitech WS-CL80D Automatic Solar Cell Layup Machine features dual gantry dual-gripper independent operation, linear motor driven main axis with 0.01mm\n\n![Automatic Tape Sticking Machine: 25s Cycle, ±2mm](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_1774350079476146.webp)\n\n- [** Rachael](./automatic-tape-sticking-machine-for-solar-panel-production-line-ooitech.html)\n- [** 81922](./automatic-tape-sticking-machine-for-solar-panel-production-line-ooitech.html)\n\n### Automatic Tape Sticking Machine: 25s Cycle, ±2mm\n\nOoitech Automatic Tape Sticking Machine applies adhesive tape on solar cell strings with high precision and speed.\n\n![String Interconnect: Solar Busbar Ribbon Guide](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_2026032713037538.jpg.webp)\n\n- [** Rachael](./Interconnection-Busbar-for-Solar-Module-Assembly-High-Performance-Current-Collection-Solution.html)\n- [** 97200](./Interconnection-Busbar-for-Solar-Module-Assembly-High-Performance-Current-Collection-Solution.html)\n\n### String Interconnect: Solar Busbar Ribbon Guide\n\nPremium interconnection busbar solutions for solar module assembly, featuring high-purity tinned copper construction\n\n![OPT-M960B EL & VI Tester: 0.1mm/pixel, Intel i7](https://cdn.ooitech.com/runtime/image/w800_h600_fitblur_v2_1774351816741704.webp)\n\n- [** Rachael](./solar-panel-el-tester-and-vi-tester-machine-opt-m960b-m951b-m950b-ooitech-solar-module-el-testing-equipment.html)\n- [** 43959](./solar-panel-el-tester-and-vi-tester-machine-opt-m960b-m951b-m950b-ooitech-solar-module-el-testing-equipment.html)\n\n### OPT-M960B EL & VI Tester: 0.1mm/pixel, Intel i7\n\nOoitech offers professional solar panel EL tester and VI tester machines (OPT-M960B, OPT-M951B, OPT-M950B) with SONY industrial cameras\n",
    "endpoints": {
        "html": "https://www.ooitech.com/uv-dose-iec-tests-outdoor-months.html",
        "markdown": "https://www.ooitech.com/uv-dose-iec-tests-outdoor-months.md",
        "agentManifest": "https://www.ooitech.com/.well-known/agent.json",
        "llmsTxt": "https://www.ooitech.com/llms.txt",
        "sitemap": "https://www.ooitech.com/sitemap.xml",
        "quote": "https://m.ooitech.com/api/quote.php"
    }
}
